How to Start a Diesel Generator That Ran Out of Fuel

by gongshang02

Hello there! I’m a diesel generator, and it’s not uncommon for me to run out of fuel from time to time. When that happens, getting me up and running again might seem like a daunting task, but with the right knowledge and steps, it can be done smoothly. In this article, I’ll guide you through the process of starting a diesel generator that has run out of fuel. Whether you’re a homeowner using me for backup power during a blackout, a small – business owner relying on me to keep operations going, or an industrial operator, these steps will be valuable. So, let’s get started on getting me back in action!​

Safety First​

Before we begin any work on starting a diesel generator that has run out of fuel, safety should be your top priority. Diesel fuel is flammable, and improper handling can lead to dangerous situations. Make sure you’re in a well – ventilated area. If you’re working indoors, open windows and doors to allow fresh air to circulate. This helps prevent the buildup of potentially explosive fuel vapors. Avoid smoking or having any open flames in the vicinity. Even a small spark can ignite the fuel vapors, so keep lighters, matches, and any other sources of ignition far away.​

Advertisements

Wear appropriate personal protective equipment (PPE). This includes safety glasses to protect your eyes from any splashing fuel or debris. Gloves are also a good idea to protect your hands from the fuel, which can be harmful if it comes into contact with your skin for an extended period. If possible, wear long – sleeved shirts and long pants to minimize skin exposure.​

Advertisements

Check the Generator​

Fuel – Level Inspection​

The first step is to confirm that I’ve indeed run out of fuel. Locate my fuel tank, which is usually a prominent part of my structure. It could be a separate tank attached to my base or an integrated one. Most fuel tanks have a fuel – level gauge. Check this gauge to see if the fuel level is at or near zero. In some cases, the gauge might be inaccurate, so it’s also a good idea to visually inspect the tank if possible. Some tanks have a translucent section or a sight glass that allows you to see the fuel level directly. If you can’t see the fuel level through a sight glass or if the tank is opaque, you can use a dipstick (if available) to measure the fuel level. Insert the dipstick into the fuel – tank opening until it reaches the bottom, then pull it out and check the fuel mark on the dipstick. If there’s no fuel on the dipstick, it’s a clear sign that I’m out of fuel.​

Advertisements

Other Component Checks​

While you’re at it, take a quick look at other important components. Check the oil level in my engine. The engine oil is crucial for lubricating the moving parts and preventing excessive wear. Locate the oil – dipstick, which is usually marked. Pull it out, wipe it clean with a rag, re – insert it fully, and then pull it out again to check the oil level. The oil should be between the minimum and maximum marks on the dipstick. If the oil level is too low, it can cause engine damage, so consider adding the appropriate type of oil if needed.​

Advertisements

Inspect the coolant level as well. The coolant helps keep my engine from overheating. Find the coolant reservoir, which is typically a plastic container with markings indicating the minimum and maximum levels. The coolant should be within the recommended range. If it’s low, add the correct coolant mixture. Be careful not to open the coolant – reservoir cap when the engine is hot, as this can cause hot coolant to spray out and burn you. Wait for the engine to cool down before checking or adding coolant.​

Also, check the battery. A weak or dead battery won’t be able to start my engine. Look for signs of corrosion on the battery terminals. If there’s corrosion, clean it off using a mixture of baking soda and water. Use a wire brush to gently scrub the terminals until they’re clean. Make sure the battery cables are tightly connected to the terminals. You can also use a multimeter to check the battery voltage. A fully charged 12 – volt battery should have a voltage of around 12.6 volts. If the voltage is significantly lower, the battery may need to be charged or replaced.​

Refueling the Generator​

Choosing the Right Fuel​

The type of diesel fuel you use in me is important. Most diesel generators are designed to run on standard diesel fuel, which is widely available at gas stations. However, there are different grades of diesel fuel, and it’s best to use the grade recommended by my manufacturer. Some generators may also be compatible with biodiesel blends, but if you choose to use biodiesel, make sure it meets the appropriate standards and is suitable for my engine. Using the wrong type of fuel can cause engine performance issues, such as poor starting, reduced power output, and increased emissions.​

Refueling Process​

Once you have the right fuel, it’s time to refuel me. First, make sure I’m turned off. This is extremely important to prevent any risk of fuel igniting while it’s being added. Locate the fuel – tank filler cap, which is usually clearly marked. Remove the cap carefully. If there’s a fuel – filter screen on the filler neck, don’t damage it while refueling. Slowly pour the diesel fuel into the tank. Try to avoid splashing the fuel, as this can create a fire hazard and also waste fuel. Fill the tank to an appropriate level. It’s not necessary to fill it to the brim; leaving a little space at the top can prevent fuel from overflowing when the tank heats up.

After refueling, securely replace the fuel – tank filler cap. Make sure it’s tightened properly to prevent fuel leaks. Check around the filler area for any spilled fuel. If there is any, clean it up immediately using an absorbent material like rags or kitty litter. Dispose of the absorbent material properly, as it contains diesel fuel and can be a fire hazard.​

Priming the Fuel System​

Understanding Fuel – System Priming​

When I run out of fuel, air can enter the fuel lines. Priming the fuel system is the process of removing this air and ensuring that fuel can flow smoothly from the tank to the engine. Without priming, the engine may not start or may start but run erratically. There are different methods of priming the fuel system, depending on the type of diesel generator.​

Manual Priming​

Some diesel generators have a manual priming pump. This is usually a small, hand – operated pump located on the fuel filter or near the fuel – injection system. To prime the fuel system manually, start by loosening the bleed screw on the fuel filter. This allows air to escape as you pump the fuel. Then, start pumping the manual priming pump. You’ll feel resistance as you pump. Keep pumping until you see a steady stream of fuel coming out of the bleed screw without any air bubbles. Once you see this, tighten the bleed screw.​

If your generator doesn’t have a manual priming pump, you can try priming the fuel system by using a fuel – transfer pump. Connect the fuel – transfer pump to the fuel – tank outlet and the inlet of the fuel – injection system. Make sure all connections are secure. Then, operate the fuel – transfer pump to force fuel through the lines and displace the air. Monitor the fuel – filter area for any signs of air escaping. Once you see a steady flow of fuel without air bubbles, you can assume the fuel system is primed.​

Automatic Priming​

Some modern diesel generators are equipped with an automatic priming system. If your generator has this feature, it simplifies the process. Usually, all you need to do is turn the key to the “on” position (without starting the engine) or press a specific priming button on the control panel. The automatic priming system will then activate a pump that circulates fuel through the system, removing air in the process. You may be able to hear the pump running. After a short period, the system should indicate that the fuel system is primed. This could be through a light on the control panel or a message on a digital display.​

Starting the Generator​

Starting Procedure for Manual – Start Generators​

If I’m a manual – start diesel generator, the starting process is a bit more hands – on. First, make sure all the controls are in the correct position. The throttle control should be set to a medium position. If it’s set too low, the engine may not start, and if it’s set too high, it can cause the engine to rev too quickly when it starts, which can be dangerous.​

Next, turn the ignition key to the “start” position. You may need to hold it there for a few seconds. As you turn the key, the starter motor will engage and begin to rotate the engine. If the engine doesn’t start right away, don’t keep the key in the “start” position for too long. Wait for a few seconds between attempts to avoid overheating the starter motor. Try starting the engine a few times. If it still doesn’t start, double – check that the fuel system is properly primed, the battery is charged, and all connections are secure.​

Starting Procedure for Automatic – Start Generators​

For automatic – start diesel generators, the process is more straightforward. Once you’ve refueled and primed the fuel system, all you need to do is make sure the generator is set to the “automatic” mode. In this mode, the generator is connected to a sensor that detects when there’s a power outage. When the power goes out, the sensor will send a signal to the generator’s control system. The control system will then automatically start the engine. You may hear a clicking sound as the control system activates the starter motor. The generator should start up within a few seconds. If it doesn’t start, check the control – system settings, the fuel system, and the battery, just like you would for a manual – start generator.​

Post – Start Checks​

Engine Performance​

Once I’ve started, it’s important to check my engine performance. Listen to the engine. It should run smoothly without any unusual noises. A knocking or rattling sound could indicate a problem with the engine, such as a problem with the pistons, valves, or bearings. If you hear any strange noises, turn off the generator immediately and have a qualified technician inspect it.​

Check the engine’s speed. Most diesel generators have a tachometer on the control panel that shows the engine’s revolutions per minute (RPM). The RPM should be within the normal operating range specified by the manufacturer. If the RPM is too high or too low, it can affect the generator’s performance and the quality of the electricity it produces. You can adjust the throttle control slightly to bring the RPM to the correct level.​

Electrical Output​

Check the electrical output of the generator. Connect a voltmeter to the generator’s output terminals to measure the voltage. The voltage should be close to the rated voltage of the generator, which is usually 120 volts, 240 volts, or a combination of both, depending on the generator model. If the voltage is significantly higher or lower than the rated voltage, it can damage the electrical equipment connected to the generator. Some generators also have an ammeter on the control panel that shows the current output. Make sure the current is within the generator’s capacity. If the generator is overloaded, it can cause the engine to work harder than it should and may lead to overheating and other problems.​

Cooling and Lubrication Systems​

Monitor the cooling and lubrication systems. Check the coolant temperature gauge on the control panel. The temperature should be within the normal operating range. If the temperature is rising too quickly or is above the normal range, it could indicate a problem with the cooling system, such as a coolant leak, a malfunctioning water pump, or a blocked radiator. Also, check the oil – pressure gauge. The oil pressure should be within the recommended range. Low oil pressure can cause engine damage, so if you notice low oil pressure, turn off the generator and check the oil level and the oil – pump.

Conclusion​

Starting a diesel generator that has run out of fuel may seem like a complex process, but by following these steps – ensuring safety, checking the generator, refueling, priming the fuel system, starting the generator, and performing post – start checks – you can get me up and running again. Remember, if you’re ever unsure about any step in the process or if you encounter any problems, it’s always a good idea to consult the generator’s user manual or contact a professional technician. With proper care and knowledge, you can keep me providing reliable power for all your needs.​